Hybrid Inverter Technical Library

Find the exact Nexus Solar Energy or Devsol hybrid inverter by capacity, battery voltage, phase and IP rating, then open its technical reference, current product page, warranty resources and relevant demonstrations below.

This technical library covers the 2kW to 15kW hybrid range. It separates similar-looking models so that PV limits, charging current and battery requirements stay tied to the correct inverter. Reference issue: 25 October 2026.

Download technical documents

Hybrid inverter model index

Choose an exact row before comparing specifications. IP21, IP54, IP65 and IP66 are different enclosure configurations. A 12kW single-phase unit is different from a 12kW three-phase unit. Current prices and availability are shown on the linked product pages.

Model and current price Battery system Enclosure Warranty*
2kW 24V IP21 24V IP21 2 years*
3kW 24V IP21 24V IP21 2 years*
INNO 9G 3kW 24V IP54 24V IP54 4 years*
3.5kW Advance 24V IP54 24V IP54 4 years*
INNO 8G 4kW 24V IP21 24V IP21 2 years*
DEV HYD 5kW 24V IP54 24V IP54 4 years*
6kW 48V Dual MPPT IP21 48V IP21 2 years*
DEV HYD 6kW 48V IP54 48V IP54 4 years*
6kW 48V Dual MPPT IP65 48V IP65 5 years*
8kW 48V Dual MPPT IP21 48V IP21 2 years*
10kW 48V IP21 48V IP21 2 years*
11kW 48V Dual MPPT IP21 48V IP21 2 years*
Devsol 12kW Single-Phase IP66 48V class; 40-60V operating range IP66 5 years*
Devsol INNO 9G 12kW Three-Phase IP66 48V class; 40-60V operating range IP66 5 years*
15kW Three-Phase IP66 48V IP66 5 years*

*Warranty is subject to the written warranty terms and the purchased model configuration.

Detailed model references

These model cards bring the published electrical values and useful resources together. Refer to the current product page and applicable installation manual when finalising a system.

INNO 9G 3kW 24V IP54

INNO 9G 3kW 24V IP54 hybrid inverter

Rated output 3kW
Battery system 24V
Enclosure IP54
Warranty 4 years*
Solar charge control MPPT
Output waveform Pure sine wave
Battery-less operation Supported on the model; available input must cover the load

View this exact model, current price and availability

DEV HYD 5kW 24V IP54

DEV HYD 5kW 24V IP54 hybrid inverter

Rated output 5kW
Battery system 24V
Enclosure IP54
Warranty 4 years*
Solar charge control 60V-450V MPPT
MPPT operating window 60-450V
Maximum PV input 9000W
Output Pure sine wave; dual AC output
Battery-less operation Supported on the model; available input must cover the load

View this exact model, current price and availability

6kW 48V Dual MPPT IP21

6kW 48V Dual MPPT IP21 hybrid inverter

Rated output 6kW
Battery system 48V
Enclosure IP21
Warranty 2 years*
Solar charge control Dual MPPT
Output waveform Pure sine wave
Battery-less operation Supported on the model; available input must cover the load

View this exact model, current price and availability

6kW 48V Dual MPPT IP65

6kW 48V Dual MPPT IP65 hybrid inverter

Rated output 6kW
Battery system 48V
Enclosure IP65
Warranty 5 years*
Solar charge control Dual MPPT
Output waveform Pure sine wave
Battery-less operation Supported on the model; available input must cover the load

View this exact model, current price and availability

DEV HYD 6kW 48V IP54

DEV HYD 6kW 48V IP54 hybrid inverter

Rated output 6kW
Battery system 48V
Enclosure IP54
Warranty 4 years*
Solar charge control 60-450V
Maximum PV input 9000W
MPPT / maximum PV Voc 60-450V / 500V
PV / AC / combined charge limit 120A / 120A / 120A
Communication interfaces RS232 / RS485 / CAN; pair-specific protocol setup applies
Output / surge 6kW / 12kVA
Output topology Single phase; dual AC output
Battery-less operation Supported
Display / monitoring 5-inch LCD; optional Wi-Fi

CAN/RS485 interfaces support a communication setup only when the selected battery protocol, firmware and cable pinout match the inverter configuration.

View this exact model, current price and availability

Devsol 12kW Single-Phase IP66

Devsol 12kW Single-Phase IP66 hybrid inverter

Rated output 12kW
Battery system 48V class; 40-60V operating range
Enclosure IP66
Warranty 5 years*
Solar charge control Dual MPPT, 2+1 PV strings
Phase Single phase
Usable PV input / maximum DC voltage 13.2kW / 500V
MPPT window / input currents 125-425V / 40A + 22A
PV trackers / strings 2 trackers / 2+1 strings
Maximum charging current 200A
Transfer time Below 10ms
Parallel capability Up to 6 units, matching configuration
Communication interfaces Wi-Fi / RS485 / CAN / DRM
Dimensions / net weight 440 x 670 x 250mm / 44kg

View this exact model, current price and availability

Devsol INNO 9G 12kW Three-Phase IP66

Devsol INNO 9G 12kW Three-Phase IP66 hybrid inverter

Rated output 12kW
Battery system 48V class; 40-60V operating range
Enclosure IP66
Warranty 5 years*
Solar charge control MPPT
Phase Three phase
Maximum PV input / DC voltage 18kW / 800V
MPPT window / input currents 200-650V / 40A + 20A
PV trackers / strings 2 trackers / 2+1 strings
Maximum charge / discharge current 260A
Rated output voltage 380 / 400 / 415V
Transfer time Below 10ms
Dimensions / net weight 440 x 260 x 700mm / 39kg

View this exact model, current price and availability

15kW Three-Phase IP66

15kW Three-Phase IP66 hybrid inverter

Rated output 15kW
Battery system 48V
Enclosure IP66
Warranty 5 years*
Solar charge control MPPT
Technical reference HN15KT-AH2GT in the supplied Devsol manual
Phase / rated AC power Three phase; 15kW / 15kVA
Maximum PV input / DC voltage 22.5kW / 1000Vdc
MPPT window / PV inputs 120-950Vdc / dual MPPT; 2 x 30A
Li-ion / lead-acid battery window 40-60Vdc / 40-57Vdc
Maximum charge / discharge current 290A
Grid / EPS voltage 230/400Vac, 3L/N/PE
Dimensions / weight 478 x 660 x 248mm / 43kg

The 15kW manual battery-output graph specifies 11.6kW at 40V and 15kW at 52–60V. Size the battery bank, BMS, wiring and protection for the required operating power. Open the matching 15kW manual.

View this exact model, current price and availability

Match the battery to the inverter

Match the actual voltage window and continuous current limits, then confirm any required BMS protocol and cable configuration. Nominal voltage alone does not establish a complete match.

  1. Record the inverter model, phase, serial number and firmware.
  2. Record the battery chemistry, voltage window, Ah/kWh and bank arrangement.
  3. Use the battery/BMS continuous charge and discharge limits to set inverter currents. The lowest applicable equipment limit governs the configuration.
  4. For BMS communication, match the named protocol, inverter/battery firmware and cable pinout. A CAN or RS485 connector alone does not identify the protocol.
  5. Retain the selected manuals, warranty record and commissioning readings with the installation.

Download the fillable matching and commissioning record or ask Nexus Solar Energy for exact-model selection support.

15kW three-phase BMS communication reference

The Devsol 15kW HN15KT-AH2GT manual specifies CAN or RS485 battery communication and the inverter-side BMS port pinout below. Use this reference for the matching unit and its supplied manual.

Inverter-side communication reference — 15kW three-phase
Inverter identity Devsol 15kW three-phase; HN15KT-AH2GT technical reference in the linked manual. Match the delivered unit nameplate.
BMS communication choices CAN or RS485, using the communication method configured on the connected battery.
Manufacturer/profile shown in the manual PYLON. This is the named inverter menu/profile; it does not identify the make of the installed BMS.
BMS RJ45 pin 1 / pin 2 RS485B / RS485A
BMS RJ45 pin 3 / pin 6 GND / GND
BMS RJ45 pin 4 / pin 5 CANH / CANL
BMS RJ45 pin 7 / pin 8 NC / NC
Bank configuration Set the actual battery/BMS count in BMS Num and retain the commissioning record.

Pin numbering follows the connector orientation in manual section 6.7.1, printed page 32 (PDF page 36). Connect the communication cable to the BMS port, not the adjacent METER/CT port. Route it through the specified waterproof gland and restore the seal.

This table describes the inverter end. Match the battery-end pinout and the approved cable to the actual battery/BMS revision; an RJ45 plug alone does not establish a straight-through cable match. Keep the inverter firmware, battery/BMS firmware, selected profile and cable part number together in the installation record.

The battery settings reference, printed page 45 (PDF page 49) shows PYLON, CAN/RS485 selection, SOC limits, maximum charge/discharge current and BMS Num. Set currents within the inverter, battery bank, BMS and cable limits. The 120A shown on that example screen is an illustration, not the 15kW model’s maximum rating.

How to compare charging current meaningfully

Compare current at the same battery voltage and within the permitted bank limits. For example, 100A at 24V nominal is approximately 2.4kW of DC charging power; 100A at 48V nominal is approximately 4.8kW. These are nominal V × A examples. Actual charging voltage, available PV/AC power, conversion losses, battery acceptance and the final charging stage affect the result. A larger Ah bank takes proportionally more energy to reach the same state of charge.

First-hand setup and load demonstrations

Use the timestamps to see the relevant setup and discussion. Match the demonstrated model, PV input, battery support and loads to the proposed installation.

Warranty, service and certification resources

For a certified purchase requirement, match the exact designation and standard in the original certificate or inclusion document to the selected product. Keep the invoice, delivered unit identification and commissioning record together.

Choose a system or compare models